Carrier 48fc 15 ton.

6 2 15.0 74 x 47 x 41 67 110 150 607 Gas Heating / Electric Cooling Models – 48FC Electric Heat / Electric Cooling & Cooling Only Models – 50FC Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimensions (in) L x W x H Electrical Heat Nominal kW Range Approx. Unit Weight (lbs) 3 1 (14.0) 74 x 47 x 33 4.0 to 15.0 437

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...Performance series air conditioners offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The Performance 17 model also goes that one step further to give you two-stage compression for comfort, quiet and enhanced summer dehumidification. California residents please see Proposition 65.IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unit48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Medium Heat. ... Carrier 6 Ton, 11.0 EER Package RTU Medium Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3 ... IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using …

Carrier 48TC Gas/Electric 15 Ton Standard Efficiency Packaged Outdoor Unit 208/230-3-60 MED Static, Medium Heat ... Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time ... PI-48FC-GC-01; Checklist - PI48TC-HC-01; Configuration - 33CS-68SI;

7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …A baby carrier offers lots of benefits and should be part of your baby traveling inventory right from the start. Here is a guide to the best. We may be compensated when you click o...

Supply Width 15.52 Return Length 37.921 Return Width 15.799 RW RL SW SL CW CL Table 5. Curb matrix Type Trane Lennox Carrier Bryant JCI/York ICP Heil Day and Nigh Goodman Daikin Older Voyager Gas/Electric GCC036-060 ZGB 036-060 48DJ 004-00, 48GJ 006 48HC 004-006, 48HE 004-006 48HJ 004-006, 48KC 004-006 48LJ 004-006, …Exceeded Department of Energy Advanced RTU Challenge by 15%; Exceeds ASHRAE 90.1 and Energy Star efficiency levels, as well as Consortium for Energy Efficiency (CEE) criteria; 3 to 5 ton models have two-stage cooling capacity control and 6 to 23 ton models have three-stage cooling capacity control; Up to 17.5 SEER and 20.8 IEERWe would like to show you a description here but the site won’t allow us.Are you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f...

2017 f150 horn replacement

els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies are

Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.42 Series AirStream™ Fan Coils. 42BH Family REVIT file. 42BV Family REVIT file. 42CA Horizontal Furred-In Family REVIT file. 42CE Horizontal Furred-In with Plenum Family REVIT file. 42CF Horizontal Furred-In, High Static Family REVIT file. 42CG Horizontal Cabinet Family REVIT file. 42CK Horizontal Cabinet, Ducted Family REVIT file.Carrier48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = 460/3/600 = Electromechanical Controls caGAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …Orissa Bengal Carrier News: This is the News-site for the company Orissa Bengal Carrier on Markets Insider Indices Commodities Currencies StocksChoosing among a broad range of air conditioner brands can be overwhelming. So we've narrowed it down to two brands, YORK® and Carrier, to help you decide. Expert Advice On Improvi...

Features. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82% …25SCA5. Up to 15.2 SEER2 for moderate energy savings with standard comfort features. 4.5 out of 5 stars. 32 Reviews. 5 Star. 69%. 4 Star. 22%. 3 Star.CarrierIEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unit CE - Carrier Enterprise CarrierView and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ...

Carrier has introduced Weather Series Rooftop Units with EcoBlueTM Technology. One of EcoBlue's many innovative features is the exclusive beltless direct-drive vane axial fan that replaces traditional belt drive fans with a simpler, more compact design for improved performance and efficiency while decreasing maintenance and installation costs.Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup-

Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. 48GC units generally comply with ASHRAE 90.1-2016 Energy Standard. Please review size specific data for compliance. 4.The 1937-1938 Mack Jr half-ton pickup was the big-rig maker's downsize experiment. See pictures and learn about the 1937-1938 Mack Jr half-ton pickup. Advertisement Mack hoped that...Are you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f...Description. Product Summary. 48TCED16A2A5-0A0G0. 48 = Gas Heat Packaged Rooftop / Unit Heat Type. TC = Standard Efficiency / Model Series - WeatherMaker™. E = … Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1. Lighter units make easy replacement. Most of Carrier’s 3--12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. Easy to maintain: Easy access handles by Carrier provide quick and easy access to all normally serviced components.American Airlines is ending the AirPass program, which offered fixed rates for travel and a ton of lucrative perks. While most travelers purchase airline tickets directly from the ...View and Download Carrier 48FC installation instructions online. Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. 48FC air conditioner pdf manual download. Also for: 48gc, 48hc, 48lc, 48tc, 582k, 581k, 581j, 580j,... Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat

Regal theater turnersville nj

Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3.

View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) …48FC 08-14 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air ...50FCQ 04 -28, 50GCQ 04-06 Single Package Rooftop Heat Pump Units with SystemVuTM Controls Version 3.X and Puron R-410A Refrigerant Controls, Start-Up, Operation and Troubleshooting Instructions IMPORTANT: This literature covers 50FCQ 04 -28 and 50GCQ 04-06 models with SystemVu controls version 3.X...Carrier roof curbs that were installed back to 1989, which makes replace-ment easy and eliminates the need for curb adapters or changing utility connections. Single-stage units deliver SEERs up to 14.3. IEERs up to 15.0 and heating HSPFs up to 8.2. All models are capable of either vertical or horizontal airflow.Carrier West Training – HVAC Trainingcarrier 48fc ton › ... Carrier 48FCFM07A3A6-0A0A0 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 460 VOLT GAS ELECTRIC RTU DCNE. 4.8 (195) · USD 30.8 · In stock. Description. The MRCOOL DIYM218HPC00C07 is a dual zone ceiling cassette mini split that offers 18,000 BTUs of cooling Free Shop now at.View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A …Carrier 48GC Series Pdf User Manuals. View online or download Carrier 48GC Series Installation Instructions ... Gas Heat (48FC and 48GC) 8. Controls Quick Set- -Up. 8. Control Set Point and Confirmation Log. 8. Initial Startup. 8. ... Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector ...Performance Features. 38AUQ Heat Pump EERs up to 11.0 and 3.5 COP. ASHRAE 90.1 Efficiency Compliant. Standard crankcase heater. Compressor vibration isolation. Low ambient temperature control. Unit performance certified in …6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ...

Puron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated withSpecification. AHRI System Builder. Description. Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: …New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.Instagram:https://instagram. how to adjust refrigerator door whirlpool Carrier provides a full line of packaged rooftop equipment to meet demanding HVAC systems requirements, from small electric cooling units to large gas heat/electric cooling units like the WeatherExpert® series, which has the industry’s highest part-load performance IEER ratings in the 3-5 ton range. Carrier DOAS (Dedicated Outdoor Air Systems) are … craigslist boise idaho boats Carrier West Training – HVAC TrainingCarrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor) trilux scope 8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 09 = 8.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability … byu commencement speaker 2023 Carrier rooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: •Single circuit, single stage cooling model on 6 ton •Single circuit, 2-stage cooling mod-els are available from 7.5 to 10 ton. •Dual circuit 2-stage cooling stage models are available from 7.5 to 15 ton. one dollar bill with blue seal Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input 250000; Compressor Stage 1; Equipment Type Commercial Packaged …48FC 08-14 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air ... husqvarna chainsaw carb adjustment tool Authorities recovered 172 gold bars scattered on the runway. By clicking "TRY IT", I agree to receive newsletters and promotions from Money and its partners. I agree to Money's Ter... how to get to mountain of giants Carrier• SEER of 14.0 (3 to 5 Ton) • IEER of 15.0 • Meets or exceeds ASHRAE 90.1 energy efficiency levels • Rated in accordance with AHRI Standards 210/240 for sizes 04 to 06 and 340/360 for size 07 • Designed in accordance with Underwriters Laboratories Std 1995 • Listed by UL and UL-Canada arbor mall shooting 6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ... how to request credit limit increase merrick bank Air Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48LJ Installation, Start-Up And Service Instructions ManualAERO® Indoor/Outdoor Small Air Handler. 39S. Construction: Compact single/double-wall. Application: Indoor, Outdoor. Airflow Range (Cfm): 400 - 8,500. Documents Details. Carrier offers custom, compact, single wall and double wall air handlers and air handling units to meet the HVAC needs of commercial customers. ichorous gloves View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,... king ranch chicken magnolia table The Performance heat pump, with two-stage compressor, lets you enjoy smooth, consistent comfort, quieter operation and improved air flow all year long. It's an extra-efficient heat pump system that also utilizes a multi-speed blower to help achieve enhanced summer dehumidification. Includes tin-plated copper coils for enhanced corrosion resistance.48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... 48FCFM07A1A5-0A0A0 - 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Standard STATIC 208/230 ... 48fcfm07a3a5-0a0a0_submittal; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input …